Close menu

Our Innovative Products

FLOWD 8020

COMPACT MOBILE X-RAY SYSTEM
OF CONVEYOR TYPE
FOR QUICK AND EFFECTIVE TESTING
OF X-RAY PERSONAL PROTECTIVE EQUIPMENT

The system aims to extremely improve and simplify a usual method of Personal Protective Equipment (PPE) testing which requires to use X-ray medical devices (CT or fluoroscopy machines) and takes a lot of time.

FLOWD 8020 makes it possible to perform nondestructive flaw-detective testing of PPE in order to approve its further using. Unique FLOWD’s software enables to obtain an actual value of lead equivalent and relative inhomogeneity of the X-ray protective material.

The device is designed in compliance with DIN 6857-2 and ONORM S 5213 and can be used for testing:

  • Various types of PPE: aprons, skirts, vests, thyroid collars and any X-ray protective materials in form of sheet X-ray protective materials in form of sheet
  • X-ray protective gypsum plasterboard, lead-impregnated plastic, lead-impregnated rubber, lead-free X-ray protective materials etc.
  • Testing the homogeneity of sheet and roll material of different density and composition

MAIN FEATURES

  • Automatic determination of lead equivalent thickness
  • Automatic determination of areas with lead equivalent thickness less than 10% in relation to a nominal value
  • Automatic coloring, depending on an actual lead equivalent thickness
  • Automatic determination of the relative material inhomogeneity of the protective material
  • Test report making mode
  • Reports archiving mode
  • Ability to operate both from device’s touch screen and from a remote PC (optionally)
  • Great portability and compactness

FLOWD SPECIFICATIONS

Weight

400 kg

Size of the inspection window

height

240 ± 5 mm

width

870 ± 3 mm

Dimensions of the inspection object

height

200 mm

width

750 mm

length

1300 mm

Power Supply

number of phases

single-phase network of general purpose

voltage range

220/110 V

current frequency

50/60 Hz

maximum power

consumption

0,5 kV · A

Maximum distributed load per conveyor

25 kg

Limit of permissible relative error of lead equivalent measurement, not exceed

±5%

Conveyor speed

0,22 ± 0,03 m / s

0,12 ± 0,03 m / s *

Spatial resolution, no worse than

0,5 lp/mm

0,9 lp/mm *



FLOWD X-ray Example

X-RAY UNIT

Anode voltage

80/100 kV

Anode current

1,2/1,0 mA

X-ray protection

Fully protected

X-ray emission

Not more than 1 μSv/h at any point at distance of 10 cm from the device

APPLICATION SCOPE

  • Test laboratories
  • Medical facilities
  • Centers of standardization, metrology and certification
  • Testing centers
  • Metrology centers, services and institutions
  • Manufacturers of x-ray protective clothing and materials
  • Manufacturers of homogeneous sheet and roll materials of different composition

FLOWD dimensions
[TypeError] 
get_class(): Argument #1 ($object) must be of type object, null given (0)
/home/xriqqrmy/public_html/linevgroup/local/templates/.default/components/bitrix/news/products/bitrix/news.detail/.default/component_epilog.php:2
#0: include
	/home/xriqqrmy/public_html/linevgroup/bitrix/modules/main/classes/general/component.php:1501
#1: CBitrixComponent->includeComponentEpilog(array)
	/home/xriqqrmy/public_html/linevgroup/bitrix/modules/main/classes/general/component.php:1068
#2: CBitrixComponent->startResultCache(integer, array)
	/home/xriqqrmy/public_html/linevgroup/bitrix/components/bitrix/news.detail/component.php:190
#3: include(string)
	/home/xriqqrmy/public_html/linevgroup/bitrix/modules/main/classes/general/component.php:615
#4: CBitrixComponent->__includeComponent()
	/home/xriqqrmy/public_html/linevgroup/bitrix/modules/main/classes/general/component.php:692
#5: CBitrixComponent->includeComponent(string, array, object, boolean)
	/home/xriqqrmy/public_html/linevgroup/bitrix/modules/main/classes/general/main.php:1072
#6: CAllMain->IncludeComponent(string, string, array, object)
	/home/xriqqrmy/public_html/linevgroup/local/templates/.default/components/bitrix/news/products/detail.php:16
#7: include(string)
	/home/xriqqrmy/public_html/linevgroup/bitrix/modules/main/classes/general/component_template.php:790
#8: CBitrixComponentTemplate->__IncludePHPTemplate(array, array, string)
	/home/xriqqrmy/public_html/linevgroup/bitrix/modules/main/classes/general/component_template.php:885
#9: CBitrixComponentTemplate->IncludeTemplate(array)
	/home/xriqqrmy/public_html/linevgroup/bitrix/modules/main/classes/general/component.php:784
#10: CBitrixComponent->showComponentTemplate()
	/home/xriqqrmy/public_html/linevgroup/bitrix/modules/main/classes/general/component.php:724
#11: CBitrixComponent->includeComponentTemplate(string)
	/home/xriqqrmy/public_html/linevgroup/bitrix/components/bitrix/news/component.php:336
#12: include(string)
	/home/xriqqrmy/public_html/linevgroup/bitrix/modules/main/classes/general/component.php:615
#13: CBitrixComponent->__includeComponent()
	/home/xriqqrmy/public_html/linevgroup/bitrix/modules/main/classes/general/component.php:692
#14: CBitrixComponent->includeComponent(string, array, NULL, boolean)
	/home/xriqqrmy/public_html/linevgroup/bitrix/modules/main/classes/general/main.php:1072
#15: CAllMain->IncludeComponent(string, string, array)
	/home/xriqqrmy/public_html/linevgroup/en/our-products/index.php:11
#16: include_once(string)
	/home/xriqqrmy/public_html/linevgroup/bitrix/modules/main/include/urlrewrite.php:184
#17: include_once(string)
	/home/xriqqrmy/public_html/linevgroup/bitrix/urlrewrite.php:2
----------